The Smoke Detection System can continuously detect several cargo holds. The sampling pipes transmit air samples from cargo holds to a smoke detector. The LCD Monitor and Alert Unit displays smoke and fault alarms, and connects to Remote Display Unit. The system complies with SOLAS Chapter 2 Regulation 13-1 Sample Extraction Smoke Detection Systems, and IEC 79, EN 50250.
Smoke Detection System contains the following sections:
Sampling lines
Sampling and analysis unit
Fans
RWU display and alarm unit
RWU remote display unit

Figure 1 Smoke DetectionSystem Framework Operating Methods The smoke detector transmits 4~20mA signals to the Sampling and Analysis Unit of Smoke Detection System. The LCD Monitor and Alert Unit displays different alarm information. When smoke concentration exceeds limit, the LCD Monitor and Alert Unit initiates visual and audible alarms. You can confirm and silence alarms by pressing pads on the panel.
System Termination

Figure 2 Smoke Detection System Termination Each section's name is as follows ① 3-way valve ② PVC pipe ③ Samping and analysis unit ④ RWU dispaly and alarm unit ⑤ Steel pipe ⑥ RWU remote display unit ⑦ Fan
Smoke Detector Jumho Electric improves reliability, stability, and consistency of the point photoelectric smoke detector by using infrared scattering technology and imported optoelectronic devices. With unique maze design, the detector is dust- and pest-proof, and anti-interferes with external light. The intrinsically safe detector, with ExiIICT6 explosive-proof mark, is applicable to zone 1, 2 in petroleum chemical industry. In addition, the detector complies with GB 3836.1-2000 Electrical Apparatus for Explosive Gas Atmospheres, Part 1: General Requirement, and GB 3836.4-2000 Electrical Apparatus for Explosive Gas Atmospheres Part 4: Intrinsic Safety I.
 Figure 3 Smoke Detector Detector Specifications
Operating voltage
12V DC~24V DC
Quiescent current
less than 60μA
Static voltage range
12V DC~24V DC
Alarm current
10 mA~30 mA
Saftey barrier
U0=28V,I0=93mA
Explosion-proof mark
ExibIICT6
Visual indicator
off=normal, steady red=alarm
Operating temperature
-10℃~+40℃
Operating humidity
less than 95%, non condensing
Atmospheric pressure
86kPa~106kPa
Dimensions
100mm (diameter) 56.2 mm(Length) (with base)
System Specifications
Channels
8-channel gas detection 8-channel pressure detection
Detection type
gas
Power requirement
24 VDC
Output range
4~20 mA
Connection
3-wire sensor
Explosion proof
Ex ib ⅡA T3
Protection grade
IP68
Operating temperature
-20℃~+60℃
Storage and transportation temperature
-40℃~+70℃
Operating humidity
10 to 90% RH, non condensing
Storage humidity
5% to 95% RH, non condensing
|
|
 |
 |
|